Diagnostic unit I plus User Manual_3-E

2020/9/25 11:57:20點擊:

Diagnostic unit I plus User Manual_3-E

Page - 1 - of 8
Diagnostic Unit I plus User Manual (V2.1)
Brief
“I plus” increases to download and upload the characteristic program of MC (MC1、MC2、MC3) main board
based on original model, and saves the downloaded characteristic program of MC board into diagnostic unit I. It
has relative software which can backup downloaded characteristic programs in computers, or can upload
characteristic programs to diagnostic unit.
When do maintenance debugging on site, “I plus” is very convenient to solve many problems for long-service life
elevator projects due to characteristic program missing in main chipset, chipset damaged, or fake chipset etc…
and will not be worried about the trouble to replace main board but no chipset.
“I plus” needs to copy some parameters when replace MC board, it only takes few steps, and debugs other items:
well teach-in(AF10), rated speed(AF16), speed correction, external call scan(AF0C).
Usage Steps
 Keys and status switch operation.
“I plus” diagnostic unit appearance(Pic 1)
Here is a USB
port 
Page - 2 - of 8
 Pic 2
a. switch from normal debugging operation interface to parameter operation interface: in Pic 2, press “+”
“-” key at the same time until the first digit dot on the right light on, and diagnostic unit will switch into parameter
copy menu showed as pic 3. If it shows as pic 3, it enters into parameter operation interface.
 Pic 3
b. switch from parameter operation interface to normal debugging operation interface : In pic 3, press “+”
“-” key at the same time until the first digit dot on the right light on, the diagnostic unit back to normal debugging
status. (From pic 3 status to pic 2 status.)
c. enter into parameter operation interface as pic 3, press “+” or “-” key, can page up or down to check parameters.
“P - - 0”, “P - - 1”…… “P - - 9”. This device can save 0~9 parameters. If the display is dark, which means
the program is empty in this number, and it display light, it means the program is valid in this number.
 Sub-Menu explanations and operations for four parameters.
a. pause at “P--0” ( at 0 parameter), press “ENT” enter key, interface will switch from pic 3 to pic 4, it shows to
enter into the Number 0 parameter menu. “0-rt” : 0 means 0 parameters, “rt” is the abbreviation of return. If press
“ENT” key, the interface will switch back from pic 4 to pic 3.
 Pic 4
b. press “-” key in pic 4, will show pic 5, “0-id” shows the ID for the number 0 saved parameter (normally, it
refers to the characteristic number of elevator ). Press “ENT” key under pic 5, it will rolling display saved
parameters ID. If the display color is dark, it means no saved parameters; it is no valid to press “ENT”, no display
parameter ID.
 Pic 5
c. press “-” key in Pic 5 , will show pic 6, and press twice “ENT” key , it will download MC board parameters into
diagnostic unit I plus. (“0-dn” , “dn” is the abbreviation of download). 
Page - 3 - of 8
 Pic 6
d. Press “-” in pic 6 to show Pic 7, and press twice “ENT” key will upload parameters from diagnostic unit to
main board and saved. If display color is dark ,it means don’t have valid parameters, and will not upload
parameters and save.
 Pic 7
 Download parameters (download parameters from main board to
diagnostic unit and save)
Change page to this interface, “0-DN’, DN is for download, and press twice “ENT” key, will download
parameters as below pictures.
When downloading, the number 3. 4 digit dot on the bottom right is blinking.
If finish parameter download, will display “SUCC” , it means to save parameters successful. 
Page - 4 - of 8
 Parameters upload. (upload parameters from diagnostic unit to main
board and save) -Must be in the inspection state
Change page to this interface, “0-UP”, it means upload, press twice “ENT” key, and will upload parameters
from diagnostic unit to main board as below pictures.
When uploading, the number 3. 4 digit dot on the bottom right is blinking
Display “SAVE ”, it means the parameters has been received successfully, and main board is saving parameters.
Please don’t touch the communication cable and diagnostic unit at this time.
It will display “SUCC” when parameters is uploaded and saved successfully. At the same time, please power off
main power supply and restart elevator main board.
 Supplementary explanation about upload and download from main
board. 
Page - 5 - of 8
If shows “E-XX” , it means the relative operation is error, Please check the main board status, communication
cable etc…
Explanations of Error codes :
E—10 error from downloading data
E—11 error from downloading data timeout
E—12 An error occurred while downloading data and fail to save.
E—00 invalid uploaded data
E—01 error from uploading data
E—02 error from uploading data timeout
E—03 version error while uploading data
E—04 error from uploading data, please restart main board
E—05 error from saving codes while uploading data.
E—06 error from saving operation while uploading data
E—20 unknown error
 Backup characteristic program to computer
 Restore characteristic program to diagnostic unit
 The code meaning when copy parameters from diagnostic unit.
Software Operations:
1. upload file from computer to diagnostic unit
1
2. open serial
port
3. select needed
spec upload to
diagnostic unit
4. select to save
specs
1. select COM
port
5. click to upload
specs to diagnostic
unit
6. uploaded spec to diagnostic
unit, successfully 
Page - 6 - of 8
2. download spec from diagnostic unit to computer
3.Illustration for spec modification
2. Input your modified spec address
and click enter to save, and select
it, the value for this address will be
changed automatically. Click”
modify” button, will show the
modified value.
3. click save to
take effect.
upline is original
value
downline is
modified value
1. upload or open the spec file, click
“spec” in menu, and select “spec modify”
1. select COM
port
2. open
serial port
3. select program Number for
needed backup to computer
4. click to download
spec
5、download spec successfully
6. click to save,
and select the
saved route.
Done. 
Page - 7 - of 8
4、data cable connection
5. the accessories for connector changes from USB to RS232 serial port.
this connector is only
for diagnostic unit,
forbid connecting with
USB of computer.
The short-line USB
connector, is 5V power
supply, when diagnostic unit
needs 5V power supply, it can
connect computer USB ,
mobile phone charges or
power charger. The short-line
USB connector is only for
power supply
9-pin RS232 serial
port is for the
connection with board
port of elevator’s MC
board or RS232 of
computer.
2 – RXD
3 – TXD
5 – GND
9 – 5V DC 
Page - 8 - of 8
Note: when diagnostic unit connects with computer, if computer is not with RS232 serial connector, will need this
accessories.
6. Distinguish
RS232 


文件下載:點擊下載Diagnostic unit I plus User Manual_3-E (點擊查看下載口令
    下載申明:(1)倍加信梯控提供的Diagnostic unit I plus User Manual_3-E資料來源于網絡收集整理,并免費提供下載Diagnostic unit I plus User Manual_3-E不收取任何費用,若發現您的權益受到侵害,請立即聯系我們,我們會立即刪除Diagnostic unit I plus User Manual_3-E資料。(2)倍加信梯控提供的Diagnostic unit I plus User Manual_3-E資料僅供用戶學習和參考,用戶如果使用下載的Diagnostic unit I plus User Manual_3-E資料造成任何損失與倍加信無關,Diagnostic unit I plus User Manual_3-E資料最終以版權廠家提供原廠資料為準。(3)倍加信梯控免費提供大量蒂森電梯技術資料下載,歡迎收藏本站,底部右下角提供了搜索功能,倍加信人臉識別梯控、IC刷卡梯控、二維碼梯控、指紋識別梯控、語音梯控、CPU梯控、ID卡梯控、手機乘梯、機器人乘梯等廣泛應用于蒂森電梯,歡迎掃碼二維碼加個微信咨詢或備用,再次感謝您在倍加信梯控免費下載蒂森電梯Diagnostic unit I plus User Manual_3-E。

主站蜘蛛池模板: 女女互磨互喷水高潮les呻吟| 国产偷窥熟女精品视频大全| 国产玉足榨精视频在线观看 | 少女高清影视在线观看动漫| 久久av高清无码| 亚洲成a人片在线观看久| 久久国产欧美日韩精品| 乱人伦人妻中文字幕无码| 色婷婷一区二区三区四区成人网| 最近中文字幕mv在线资源| 天天做天天爱夜夜爽| 92电影网午夜福利| 日日躁夜夜躁狠狠躁夜夜躁| 丰腴饱满的极品熟妇| 日韩人妻无码精品系列| 欧美成人午夜免费影院手机在线看| 亚洲欧美国产精品专区久久| 无码h黄肉动漫在线观看网站| 黑人大群体交免费视频| 欧美bestiality变态人禽交| 国产高潮流白浆视频| 国产精品亚洲色婷婷99久久精品| 午夜免费福利小电影| 国产98色在线 | 国产| 毛片免费全部播放无码| 欧美丰满大屁股ass| 鲁丝一区二区三区免费| 成人做受视频试看60秒| 一个人看的www免费视频中文| 国产精品久久久久久亚洲影视| 美女极度色诱视频国产| 国产一区二区三区四区五区加勒比 | 日韩精品久久无码中文字幕| 中文字幕乱偷无码av先锋| 激情按摩系列片aaaa| 日本护士xxxxhd少妇| 婷婷综合另类小说色区| 中文字幕久久熟女蜜桃| 特黄a级毛片免费视频| 欧美一线二线三显卡| 国产大片内射1区2区|